NJBF
Home  
home > support > mid-range >2620 operator manual

 

Support
2620 Power Feeder Operator Manual

 
Description
Spring Block Installation
Setting up the 2612 Folder/Sealer
2620 Power Feeder Set-Up
2620 Basic Operation
Troubleshooting

 

DESCRIPTION

WHEN OPENING THE 2620 POWER FEEDER THERE SHOULD BE THREE SEPARATE PACKAGES WITH THE PICTURES SHOWN BELOW.

SIDE LATCH PACKAGE TO SECURE THE 2620 POWER FEEDER AND THE 2612 FOLDER/SEALER.

STACKER EXTENSION PACKAGE TO ACCOMMODATE DIFFERENT FORM LENGTHS.

SPRING BLOCK PACKAGE THIS IS ONLY REQUIRED IF YOUR 2612 FOLDER/SEALER HAS SPRING TENSIONERS.

 

2620 SPRING BLOCK INSTALLATION

Kit Includes: a: Spring Block Handle

B: Left & Right Blocks

Set the spring block handle between the lower mounting pin and the spring-loaded lever.

Rotate the spring block handle until the spring-loaded lever bottoms out. Do not over rotate.

Slip the spring block so that the grooves on the block line up with the edges of the rectangular hole on the side frame.

Remove the handle. Repeat on the other side.

 

SETTING UP THE 2612 FOLDER/SEALER

Adjust the height of the 2612 Folder/sealer. Use a 5/8" open-end wrench, loosen the nut of the glides. From the tabletop, measure approximately 1 1/8" to the bottom of the plastic side covers.

Plug the right angle power cord into the 2612.

 

2620 POWER FEEDER SETUP

Locate the mounting pins on the 2612 Folder/Sealer. Line up and set the mounting notches of the 2620 Feeder to the mounting pins.

Install side latch on the mounting pin. The two slots line up with two holes on the 2620 Feeder.

Secure side latch with two thumbscrews.

Install side latches with gear cover on the operator side and secure with two thumbscrews.

 

2620 BASIC OPERATION

The 2620 Power Feeder provides double free steady forms to the 2612 Folder/Sealer. Attach the stacker extension using the two knobs provided.

Load the forms and adjust the width using the right tray guide on top of your 2620 Power Feeder.

The double detector is set at the factory for most forms. When setting up your 2620 check the double detector to the form. Take one sheet of the form and fold it in half and put it through the rollers of the double detector. Adjust the double detector knob at the top of the feeder so the red light will come on when two forms go through at the same time.

Then push the start button on top of the 2620 feeder. The two gray rollers will touch the forms first, this will start the gray rollers to take the forms forward to the rollers of the 2612 Folder/Sealer. The pick off height is set at the factory, the knob will allow you to adjust the gray rollers. When the gray rollers eventually wear out, the operator may easily replace them by removing the two blue clips.

If a double occurs the red light should come on. If this should happen, push the top button and the stack will go down. Then pull the forms that caused the jam from the feeder and restack them. Then push the top button and the 2620 Power Feeder should be working properly. NOTE: You don’t have to wait until the stack reaches the bottom to restart the feeder.

 

TROUBLESHOOTING

PROBLEM DESCRIPTION POSSIBLE CAUSE SOLUTION
Elevator does not raise
Power is not attached to the feeder.
Check power supply
  Power supply is not plugged into the wall outlet.
Check wall outlet
  There is a failure on the feeder circuit board.
Contact Tech Support for assistance
Feeder is feeding multiple pieces of media.
Media is bound together in some way.
"Fan" media to loosen it, or inspect envelopes for flap overlapping or improper construction
  Pick off height should be lowered.
Use the pick off height knob to lower the gray rollers.
  Feed rollers are in need of cleaning or replacement.
Clean rollers with water, and lint free cloth. If rollers have over 100,000 feeds on them, it is recommended that they be replaced.
Feed rollers "slip" on media
Rollers are in need of cleaning or replacement.
Clean rollers with water as outlined above or contact Tech Support for assistance for replacement roller kit.
  Side guides are set too tight.
Adjust side guides so that forms can move freely between them.
  Pick off height is too low.
Raise pick off height using the pick off height knob on the top of the machine.

 

© 2002-2012, Infoseal.
Infoseal, LLC • 1825 Blue Hills Circle • Roanoke, Virginia • 24012 • 1.888.952.4636 • Fax 888.652.4636